A new diagnostic beamline connected directly to the MAX IV linear accelerator is under construction.
It will enable time-resolved characterization of primarily the ultrashort electron bunches for the FemtoMAX beamline but will also be useful for other time-resolved experiments. The design of the highly specialized beamline components is to a large part done in-house.
Head up and tail down
The linear accelerator accelerates electrons up to high energies. Short bunches containing 109 electrons are delivered from the linear accelerator to make X-ray pulses for the FemtoMAX beamline. The duration of the bunches is in the femtosecond (10-15 s) regime to enable high temporal-resolution measurements at the beamline. The short duration makes the bunches very challenging to characterize with time resolution as conventional detection devices are too slow.
In the new setup, two so-called transverse deflecting cavities (TDC) will make the acquisition of time-resolved data possible. They will in principle add an electromagnetic field that deflects the head of the electron bunch upwards and the tail down so that the first electrons hitting the beam profile analyzer will end up at the top of the screen and the last ones will end up at the bottom. The resulting streak gives a time-resolved measurement of the shape of the bunch but the method will also be used to characterize for example how emittance and energy vary as a function of time.
– Today we rely on calculations and relative measurements for the bunch length delivered to FemtoMAX says project leader Erik Mansten, the TDC is a way for us to verify what we deliver. It also helps us preparing the linac for a possible free electron laser in the future.
>Read more on the MAX IV website